Failing gracefully

Failing gracefully: emergency mode instead of standstill, switch off unimportant loads first and only return to normal operation after stable readings.

Lesson 20 min Week 46

What you learn today

  • Emergency mode instead of standstill
  • Switch off partial functions
  • Return

The CO₂ sensor in the living module fails. What should the filtration do? A cautious chip switches everything off because it does not know anything any more – and after an hour the air runs short. A good chip keeps working, just differently.

Emergency mode instead of standstill

Think about every sensor: what is the most sensible operation without it?

FailureEmergency mode
CO₂ sensorfilter runs all the time – costs power, but the air stays good
temperature sensorheater off, warning on
airlock pressure sensordoors closed, no pump
battery readingcomfort loads off

The emergency mode is worse than normal operation, but better than nothing at all. And it is visible: a display or a flashing light says that things are not normal right now.

Switching off partial functions

Not everything is equally important. Decide on an order: air before light, light before workshop. If power gets short or the filter runs at full load in emergency mode, the unimportant loads leave the grid first. Life support stays until the very end.

Returning

When the sensor comes back, the chip should work normally again – but not on the first valid value. A loose data cable would otherwise switch between normal and emergency mode every tick. That is why the chip counts how many passes in a row the value was valid:

snanz tmp co2
add good good 1
mul good good tmp          # invalid value: back to 0
min good good STABIL
sge normal good STABIL     # only after STABIL good passes

A single invalid value resets the counter. Only after three good passes does “normal” apply again.

Tip

The same counter also gives you a gentle start: right after inserting it is at 0, so the chip begins in emergency mode and only switches over after a few ticks. Better to filter a little too much than once too little.

Exercise

Task

The filtration “Luftfilter” runs normally by CO₂ (sensor “Luft”): on above 1 %, off below 0.5 % – switched as always via On and Mode. Without a valid CO₂ value it runs all the time (emergency mode), and it only returns to normal operation after 3 valid passes. The light “Komfort” switches off below 20 % battery (battery “Akku”) and back on from 30 % – and is always off in emergency mode. The display “Betrieb” shows 0 for normal and 1 for emergency mode, the flashing light “Notbetrieb” is lit in emergency mode.

Hints

Hint 1

The counter: add good good 1, then mul good good tmp with tmp = snanz co2, then min and sge normal good STABIL.

Hint 2

Compute the filter with hysteresis first, then select filter normal filter 1.

Hint 3

Comfort with hysteresis as in load shedding, finally and comfort comfort normal.

Quiz

4 questions. You pass from 60 % – the server does the grading.

Complete the day

  • Passed the simulator exercise
  • Passed the quiz with at least 60 %

Without an account progress is saved in this browser only.

Report a mistake in this lesson

Please sign in to report. Sign in

Esc
↑ ↓ selectEnter open/ opens search anywhere