Overview
Advanced AC Suit (ItemSuitAdvancedAC) in Stationeers: clothing, hash 1447327071, 100 L. With 63 IC10 logic values.
There is no written explanation for this entry yet. All values below come straight from the game.
IC10 and logic
63 logic values, 63 readable and 11 writable.
-
PowerR 1 -
ErrorRW 4 -
PressureR 5 -
TemperatureR 6 -
PressureExternalR 7 -
ActivateRW 9 -
LockRW 10 -
SettingRW 12 -
RatioOxygenR 14 -
RatioCarbonDioxideR 15 -
RatioNitrogenR 16 -
RatioPollutantR 17 -
RatioMethaneR 18 -
RatioWaterR 19 -
OnRW 28 -
TotalMolesR 66 -
VolumeRW 67 -
PressureSettingRW 71 -
TemperatureSettingRW 72 -
TemperatureExternalR 73 -
FiltrationRW 74 -
AirReleaseRW 75 -
PositionXR 76 -
PositionYR 77 -
PositionZR 78 -
VelocityMagnitudeR 79 -
VelocityRelativeXR 80 -
VelocityRelativeYR 81 -
VelocityRelativeZR 82 -
RatioNitrousOxideR 83 -
PrefabHashR 84 -
CombustionR 98 -
SoundAlertRW 175 -
RatioLiquidNitrogenR 177 -
RatioLiquidOxygenR 183 -
RatioLiquidMethaneR 188 -
RatioSteamR 193 -
RatioLiquidCarbonDioxideR 199 -
RatioLiquidPollutantR 204 -
RatioLiquidNitrousOxideR 209 -
ReferenceIdR 217 -
ForwardXR 227 -
ForwardYR 228 -
ForwardZR 229 -
OrientationR 230 -
VelocityXR 231 -
VelocityYR 232 -
VelocityZR 233 -
EntityStateR 239 -
RatioHydrogenR 252 -
RatioLiquidHydrogenR 253 -
RatioPollutedWaterR 254 -
RatioHydrazineR 283 -
RatioLiquidHydrazineR 284 -
RatioLiquidAlcoholR 285 -
RatioHeliumR 286 -
RatioLiquidSodiumChlorideR 287 -
RatioSilanolR 288 -
RatioLiquidSilanolR 289 -
RatioHydrochloricAcidR 290 -
RatioLiquidHydrochloricAcidR 291 -
RatioOzoneR 292 -
RatioLiquidOzoneR 293
Values per slot (slot logic)
| Slot value | readable in slot | writable in slot | Number |
|---|---|---|---|
Occupied | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 | – | 1 |
OccupantHash | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 | – | 2 |
Quantity | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 | – | 3 |
Damage | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 | – | 4 |
Pressure | 0, 1 | – | 8 |
Temperature | 0, 1 | – | 9 |
Charge | 3 | – | 10 |
ChargeRatio | 3 | – | 11 |
Class | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 | – | 12 |
MaxQuantity | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 | – | 15 |
PrefabHash | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 | – | 17 |
FilterType | 6, 7, 8 | – | 25 |
ReferenceId | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 | – | 26 |
This thing is not on the data network itself. Read its values through the slot it sits in, or through db if the chip is inside it.
Academy: devices by name Academy: batch modes IC10 academy IC10 editor
Slots and modes
| # | Slot | Takes |
|---|---|---|
| 0 | Air Tank | GasCanister |
| 1 | Waste Tank | GasCanister |
| 2 | Coolant Tank | LiquidCanister |
| 3 | Battery | Battery |
| 4 | Chip | ProgrammableChip |
| 5 | Mod | SuitMod |
| 6 | Filter1 | GasFilter |
| 7 | Filter2 | GasFilter |
| 8 | Filter3 | GasFilter |
| 9 | Back | Back |
Manufacturing
There is no manufacturing recipe for this.
Material, fire and recycling
Flammable according to game data: flash point 393.2 K (120 °C); Autoignition 573.2 K (300 °C); burn time 15 s
Heat exchange (factor × surface): radiation 0.147, convection 0, sun 1.47
Raw values from the game code (14)
Field names as in the game code, untranslated. Useful for mods and exact limits.
SuitBase.pressurePerTick | 101.3 |
SuitBase.airTankSlotId | 0 |
SuitBase.wasteTankSlotId | 1 |
SuitBase.coolantTankSlotId | 2 |
SuitBase.batterySlotId | 3 |
SuitBase.chipSlotId | 4 |
SuitBase.modSlotId | 5 |
SuitBase.filterSlot1Id | 6 |
SuitBase.filterSlot2Id | 7 |
SuitBase.filterSlot3Id | 8 |
SuitBase.backSlot | 9 |
SuitBase.FilterQuantitySum | 0 |
SuitBase.maxEnergy | 4,000 |
AtmosphericItem.volume | 100 |