stationeers.de Mod workshop · Dominik1199
DE Sign in
  1. Home
  2. Stationeers wiki
  3. Devices
  4. Crew Module Active Vent

Devices

Crew Module Active Vent

PrefabStructureCrewModuleActiveVent Hash-1817129150in the hash lookup
Space flight paintable Game 0.2.6428.27798

Overview

Crew Module Active Vent (StructureCrewModuleActiveVent) in Stationeers: device, hash -1817129150, 100 W. With build steps, 47 IC10 logic values and…

There is no written explanation for this entry yet. All values below come straight from the game.

IC10 and logic

47 logic values, 47 readable and 7 writable.

  • Power R 1
  • Open RW 2
  • Mode RW 3
  • Error R 4
  • PressureExternal RW 7
  • PressureInternal RW 8
  • Lock RW 10
  • Setting RW 12
  • Maximum R 23
  • Ratio R 24
  • On RW 28
  • RequiredPower R 33
  • PrefabHash R 84
  • PressureOutput R 126
  • TemperatureOutput R 127
  • RatioOxygenOutput R 128
  • RatioCarbonDioxideOutput R 129
  • RatioNitrogenOutput R 130
  • RatioPollutantOutput R 131
  • RatioMethaneOutput R 132
  • RatioWaterOutput R 133
  • RatioNitrousOxideOutput R 134
  • TotalMolesOutput R 135
  • CombustionOutput R 148
  • RatioLiquidNitrogenOutput R 180
  • RatioLiquidOxygenOutput R 186
  • RatioLiquidMethaneOutput R 191
  • RatioSteamOutput R 196
  • RatioLiquidCarbonDioxideOutput R 202
  • RatioLiquidPollutantOutput R 207
  • RatioLiquidNitrousOxideOutput R 212
  • ReferenceId R 217
  • NameHash R 268
  • RatioHydrogenOutput R 296
  • RatioLiquidHydrogenOutput R 300
  • RatioPollutedWaterOutput R 304
  • RatioHydrazineOutput R 308
  • RatioLiquidHydrazineOutput R 312
  • RatioLiquidAlcoholOutput R 316
  • RatioHeliumOutput R 320
  • RatioLiquidSodiumChlorideOutput R 324
  • RatioSilanolOutput R 328
  • RatioLiquidSilanolOutput R 332
  • RatioHydrochloricAcidOutput R 336
  • RatioLiquidHydrochloricAcidOutput R 340
  • RatioOzoneOutput R 344
  • RatioLiquidOzoneOutput R 348

Example: address by name

Reads Setting, shows the value on the IC housing and writes On. Name the device with the labeller first; devices with the same name are addressed together.

# Crew Module Active Vent address by name
define DEVICE -1817129150  # StructureCrewModuleActiveVent
define NAME HASH("Crew Module Active Vent")  # name in game (labeller)
define TARGET 1  # On 1 = on
alias value r0

start:
yield
lbn value DEVICE NAME Setting 0  # 0 = average of all with this name
bnan value start  # no device with this name
s db Setting value  # show on the housing
sbn DEVICE NAME On TARGET  # set value
j start

Connections

12
Schematic: inputs left, outputs right, waste on top, power and data at the bottom. Position and spacing do not match the model.
  1. 1Power and data
  2. 2Gas pipe

Slots and modes

Modes: 0 = Outward, 1 = Inward

Building and deconstruction

Grid: small grid (0.5 m) · mounting: free in the grid

  1. 1

    Place

    Take back with Hand Drill

Total material

Deconstruction returns

Built with: Kit (Active Vent)

Material, fire and recycling

Flammable according to game data: flash point 373.2 K (100 °C); Autoignition 573.2 K (300 °C); burn time 30 s

Raw values from the game code (5)

Field names as in the game code, untranslated. Useful for mods and exact limits.

DeviceAtmospherics.outputSetting50
DeviceAtmospherics.pressurePerTick10
DeviceAtmospherics.MinSetting0
DeviceAtmospherics.MaxSetting100
DeviceAtmospherics.ConnectionTypeExhaustive

See also

Esc
↑ ↓ selectEnter open/ opens search anywhere