stationeers.de Mod workshop · Dominik1199
DE Sign in
  1. Home
  2. Stationeers wiki
  3. Devices
  4. Industrial Filtration

Devices

Industrial Filtration

PrefabStructureIndustrialFiltration Hash1167018773in the hash lookup
Pipes and atmosphere not in the Stationpedia paintable Game 0.2.6428.27798

Overview

Industrial Filtration (StructureIndustrialFiltration) in Stationeers: device, hash 1167018773, 10 W. With build steps, 77 IC10 logic values and connection…

There is no written explanation for this entry yet. All values below come straight from the game.

IC10 and logic

77 logic values, 77 readable and 5 writable.

  • Power R 1
  • Open RW 2
  • Mode RW 3
  • Error R 4
  • Lock RW 10
  • Setting RW 12
  • Maximum R 23
  • Ratio R 24
  • On RW 28
  • RequiredPower R 33
  • PrefabHash R 84
  • PressureOutput R 126
  • TemperatureOutput R 127
  • RatioOxygenOutput R 128
  • RatioCarbonDioxideOutput R 129
  • RatioNitrogenOutput R 130
  • RatioPollutantOutput R 131
  • RatioMethaneOutput R 132
  • RatioWaterOutput R 133
  • RatioNitrousOxideOutput R 134
  • TotalMolesOutput R 135
  • PressureOutput2 R 136
  • TemperatureOutput2 R 137
  • RatioOxygenOutput2 R 138
  • RatioCarbonDioxideOutput2 R 139
  • RatioNitrogenOutput2 R 140
  • RatioPollutantOutput2 R 141
  • RatioMethaneOutput2 R 142
  • RatioWaterOutput2 R 143
  • RatioNitrousOxideOutput2 R 144
  • TotalMolesOutput2 R 145
  • CombustionOutput R 148
  • CombustionOutput2 R 149
  • RatioLiquidNitrogenOutput R 180
  • RatioLiquidNitrogenOutput2 R 181
  • RatioLiquidOxygenOutput R 186
  • RatioLiquidOxygenOutput2 R 187
  • RatioLiquidMethaneOutput R 191
  • RatioLiquidMethaneOutput2 R 192
  • RatioSteamOutput R 196
  • RatioSteamOutput2 R 197
  • RatioLiquidCarbonDioxideOutput R 202
  • RatioLiquidCarbonDioxideOutput2 R 203
  • RatioLiquidPollutantOutput R 207
  • RatioLiquidPollutantOutput2 R 208
  • RatioLiquidNitrousOxideOutput R 212
  • RatioLiquidNitrousOxideOutput2 R 213
  • ReferenceId R 217
  • NameHash R 268
  • RatioHydrogenOutput R 296
  • RatioHydrogenOutput2 R 297
  • RatioLiquidHydrogenOutput R 300
  • RatioLiquidHydrogenOutput2 R 301
  • RatioPollutedWaterOutput R 304
  • RatioPollutedWaterOutput2 R 305
  • RatioHydrazineOutput R 308
  • RatioHydrazineOutput2 R 309
  • RatioLiquidHydrazineOutput R 312
  • RatioLiquidHydrazineOutput2 R 313
  • RatioLiquidAlcoholOutput R 316
  • RatioLiquidAlcoholOutput2 R 317
  • RatioHeliumOutput R 320
  • RatioHeliumOutput2 R 321
  • RatioLiquidSodiumChlorideOutput R 324
  • RatioLiquidSodiumChlorideOutput2 R 325
  • RatioSilanolOutput R 328
  • RatioSilanolOutput2 R 329
  • RatioLiquidSilanolOutput R 332
  • RatioLiquidSilanolOutput2 R 333
  • RatioHydrochloricAcidOutput R 336
  • RatioHydrochloricAcidOutput2 R 337
  • RatioLiquidHydrochloricAcidOutput R 340
  • RatioLiquidHydrochloricAcidOutput2 R 341
  • RatioOzoneOutput R 344
  • RatioOzoneOutput2 R 345
  • RatioLiquidOzoneOutput R 348
  • RatioLiquidOzoneOutput2 R 349

Values per slot (slot logic)

Slot valuereadable in slotwritable in slotNumber
Occupied0, 1, 2, 3, 4, 5, 6–1
OccupantHash0, 1, 2, 3, 4, 5, 6–2
Quantity0, 1, 2, 3, 4, 5, 6–3
Damage0, 1, 2, 3, 4, 5, 6–4
Class0, 1, 2, 3, 4, 5, 6–12
MaxQuantity0, 1, 2, 3, 4, 5, 6–15
PrefabHash0, 1, 2, 3, 4, 5, 6–17
SortingClass0, 1, 2, 3, 4, 5, 6–24
FilterType1, 2, 3, 4, 5, 6–25
ReferenceId0, 1, 2, 3, 4, 5, 6–26
FreeSlots0, 1, 2, 3, 4, 5, 6–31
TotalSlots0, 1, 2, 3, 4, 5, 6–32

Example: address by name

Reads Setting, shows the value on the IC housing and writes On. Name the device with the labeller first; devices with the same name are addressed together.

# Industrial Filtration address by name
define DEVICE 1167018773  # StructureIndustrialFiltration
define NAME HASH("Industrial Filtration")  # name in game (labeller)
define TARGET 1  # On 1 = on
alias value r0

start:
yield
lbn value DEVICE NAME Setting 0  # 0 = average of all with this name
bnan value start  # no device with this name
s db Setting value  # show on the housing
sbn DEVICE NAME On TARGET  # set value
j start

Connections

3Gas412
Schematic: inputs left, outputs right, waste on top, power and data at the bottom. Position and spacing do not match the model.
  1. 1Data
  2. 2Power
  3. 3Gas pipe · output
  4. 4Gas pipe · waste

Slots and modes

#SlotTakes
0Programmable ChipProgrammableChip
1Gas FilterGasFilter
2Gas FilterGasFilter
3Gas FilterGasFilter
4Gas FilterGasFilter
5Gas FilterGasFilter
6Gas FilterGasFilter

Modes: 0 = Idle, 1 = Active

Building and deconstruction

Grid: large grid (2 m) · mounting: free in the grid

  1. 1

    Place

    Take back with Hand Drill

Total material

Deconstruction returns

Raw values from the game code (5)

Field names as in the game code, untranslated. Useful for mods and exact limits.

DeviceAtmospherics.outputSetting50
DeviceAtmospherics.pressurePerTick200
DeviceAtmospherics.MinSetting0
DeviceAtmospherics.MaxSetting100
DeviceAtmospherics.ConnectionTypeFlatExhaustive
Esc
↑ ↓ selectEnter open/ opens search anywhere