stationeers.de Mod workshop · Dominik1199
DE Sign in
  1. Home
  2. Stationeers wiki
  3. Devices
  4. LArRE Dock (Atmos)

Devices

LArRE Dock (Atmos)

PrefabStructureLarreDockAtmos Hash1978422481in the hash lookup
General paintable Game 0.2.6428.27798

Overview

LArRE Dock (Atmos) (StructureLarreDockAtmos) in Stationeers: device, hash 1978422481, 10 W, 500 L. With build steps, 66 IC10 logic values and connection…

There is no written explanation for this entry yet. All values below come straight from the game.

IC10 and logic

66 logic values, 66 readable and 7 writable.

  • Power R 1
  • Open RW 2
  • Mode RW 3
  • Error R 4
  • Pressure R 5
  • Temperature R 6
  • PressureExternal RW 7
  • PressureInternal RW 8
  • Activate RW 9
  • Setting RW 12
  • RatioOxygen R 14
  • RatioCarbonDioxide R 15
  • RatioNitrogen R 16
  • RatioPollutant R 17
  • RatioMethane R 18
  • RatioWater R 19
  • On RW 28
  • RequiredPower R 33
  • Idle R 37
  • TotalMoles R 66
  • PositionX R 76
  • RatioNitrousOxide R 83
  • PrefabHash R 84
  • Combustion R 98
  • PressureInput R 106
  • TemperatureInput R 107
  • RatioOxygenInput R 108
  • RatioCarbonDioxideInput R 109
  • RatioNitrogenInput R 110
  • RatioPollutantInput R 111
  • RatioMethaneInput R 112
  • RatioWaterInput R 113
  • RatioNitrousOxideInput R 114
  • TotalMolesInput R 115
  • CombustionInput R 146
  • RatioLiquidNitrogen R 177
  • RatioLiquidNitrogenInput R 178
  • RatioLiquidOxygen R 183
  • RatioLiquidOxygenInput R 184
  • RatioLiquidMethane R 188
  • RatioLiquidMethaneInput R 189
  • RatioSteam R 193
  • RatioSteamInput R 194
  • RatioLiquidCarbonDioxide R 199
  • RatioLiquidCarbonDioxideInput R 200
  • RatioLiquidPollutant R 204
  • RatioLiquidPollutantInput R 205
  • RatioLiquidNitrousOxide R 209
  • RatioLiquidNitrousOxideInput R 210
  • ReferenceId R 217
  • RatioHydrogen R 252
  • RatioLiquidHydrogen R 253
  • RatioPollutedWater R 254
  • NameHash R 268
  • Extended R 272
  • RatioHydrazine R 283
  • RatioLiquidHydrazine R 284
  • RatioLiquidAlcohol R 285
  • RatioHelium R 286
  • RatioLiquidSodiumChloride R 287
  • RatioSilanol R 288
  • RatioLiquidSilanol R 289
  • RatioHydrochloricAcid R 290
  • RatioLiquidHydrochloricAcid R 291
  • RatioOzone R 292
  • RatioLiquidOzone R 293

Values per slot (slot logic)

Slot valuereadable in slotwritable in slotNumber
Occupied0–1
OccupantHash0–2
Quantity0–3
Damage0–4
Class0–12
MaxQuantity0–15
PrefabHash0–17
SortingClass0–24
FilterType0–25
ReferenceId0–26
FreeSlots0–31
TotalSlots0–32

Example: address by name

Reads Temperature, shows the value on the IC housing and writes On. Name the device with the labeller first; devices with the same name are addressed together.

# LArRE Dock (Atmos) address by name
define DEVICE 1978422481  # StructureLarreDockAtmos
define NAME HASH("LArRE Dock (Atmos)")  # name in game (labeller)
define TARGET 1  # On 1 = on
alias value r0

start:
yield
lbn value DEVICE NAME Temperature 0  # 0 = average of all with this name
bnan value start  # no device with this name
s db Setting value  # show on the housing
sbn DEVICE NAME On TARGET  # set value
j start

Connections

123
Schematic: inputs left, outputs right, waste on top, power and data at the bottom. Position and spacing do not match the model.
  1. 1Robotic arm rail
  2. 2Robotic arm rail
  3. 3Power and data

Slots and modes

#SlotTakes
0GasFilter

Modes: 0 = Outward, 1 = Inward

Building and deconstruction

Grid: small grid (0.5 m) · mounting: free in the grid

  1. 1

    Place

    Take back with Hand Drill

  2. 2

    Build stage 2

    Take back with Hand Drill

Built with: Kit (LArRE Dock Atmos)

Material, fire and recycling

Heat exchange (factor × surface): radiation 0, convection 0, sun 0

Raw values from the game code (3)

Field names as in the game code, untranslated. Useful for mods and exact limits.

RoboticArmDockAtmos.PressurePerTick101.3
RoboticArmDock._moveSpeed1.3
RoboticArmRailDeviceBase.ConnectionTypeFlatExhaustive

See also

Esc
↑ ↓ selectEnter open/ opens search anywhere