stationeers.de Mod workshop · Dominik1199
DE Sign in
  1. Home
  2. IC10 academy
  3. Day 161

Day 161 of 365 · Advanced · Month 6: Atmosphere and control

Review week 23: control engineering

Twelve questions on control engineering: P controller, I term and anti-windup, D term and smoothing, tuning with the stack and cascades of air conditioners.

Review 12 min Week 23

What you learn today

  • Quiz on P, PI, PID and cascades

This week you learned to drive devices smoothly instead of just switching them:

  • P controller: output = KP · error. You choose the gain from the error at which the device should run at full power. A steady-state error remains.
  • PI controller: the I term adds up the error per tick and removes the remainder. Anti-windup with clamp, NaN check before accumulating.
  • D term: from the change of the reading, with smoothing against noise. Often hysteresis or PI is enough.
  • Tuning: count sign changes, change one value after the other, keep the history as a ring buffer in the stack.
  • Cascades: two air conditioners with small jumps, Setting always below the inlet temperature, stage 2 only when needed.
  • Project: PI heater controller with pulse width for the wall heater.

You pass from 60 %. The explanations after handing in sum up every point once more.

Weekly quiz

12 questions. You pass from 60 % – the server does the grading.

Complete the day

  • Passed the quiz with at least 60 %

Without an account progress is saved in this browser only.

Report a mistake in this lesson

Please sign in to report. Sign in

Esc
↑ ↓ selectEnter open/ opens search anywhere