Overview
Small Tank (StructureTankSmall) in Stationeers: device, hash 1013514688, 10 W, 6,000 L. With build steps, 73 IC10 logic values and connection diagram.
The small tank holds 6,000 litres of gas. In this version it is a device of its own with a data port: you can read Pressure, Temperature, TotalMoles, Volume and the fractions of all gases directly from the tank. Base draw is 10 W.
Important for new saves: since version 0.2.6143 tanks are part of the pipe network. The Kit (Tank) now builds the Small Tank – same volume, but without a data port and without logic. This old version only survives in older saves. You measure the in-line tank with a Pipe Analyzer on the same network.
The old version has its own inner volume that equalises with the connected pipe network every tick. That has a noticeable effect: a pump on the pipe gets at most the pipe volume per tick. Filling and emptying therefore take much longer than with an in-line tank.
How much fits: at 20,000 kPa and 20 °C it is n = 20,000 · 6,000 / (8.3144 · 293.15) ≈ 49,200 mol. From a 60,795 kPa difference to the surroundings the tank takes 5 damage per tick. If it is destroyed, its entire contents end up in a single cell – a huge pressure surge with that amount. So fill it with a margin and remember that heat raises the pressure.
According to the game data this tank is not flammable. How to fill stores safely is covered in Tanks and gas storage: sizes, insulation, safe filling.
IC10 and logic
73 logic values, 73 readable and 2 writable.
-
OpenRW 2 -
PressureR 5 -
TemperatureR 6 -
SettingRW 12 -
RatioOxygenR 14 -
RatioCarbonDioxideR 15 -
RatioNitrogenR 16 -
RatioPollutantR 17 -
RatioMethaneR 18 -
RatioWaterR 19 -
MaximumR 23 -
RatioR 24 -
TotalMolesR 66 -
VolumeR 67 -
RatioNitrousOxideR 83 -
PrefabHashR 84 -
CombustionR 98 -
PressureOutputR 126 -
TemperatureOutputR 127 -
RatioOxygenOutputR 128 -
RatioCarbonDioxideOutputR 129 -
RatioNitrogenOutputR 130 -
RatioPollutantOutputR 131 -
RatioMethaneOutputR 132 -
RatioWaterOutputR 133 -
RatioNitrousOxideOutputR 134 -
TotalMolesOutputR 135 -
CombustionOutputR 148 -
RatioLiquidNitrogenR 177 -
RatioLiquidNitrogenOutputR 180 -
VolumeOfLiquidR 182 -
RatioLiquidOxygenR 183 -
RatioLiquidOxygenOutputR 186 -
RatioLiquidMethaneR 188 -
RatioLiquidMethaneOutputR 191 -
RatioSteamR 193 -
RatioSteamOutputR 196 -
RatioLiquidCarbonDioxideR 199 -
RatioLiquidCarbonDioxideOutputR 202 -
RatioLiquidPollutantR 204 -
RatioLiquidPollutantOutputR 207 -
RatioLiquidNitrousOxideR 209 -
RatioLiquidNitrousOxideOutputR 212 -
ReferenceIdR 217 -
RatioHydrogenR 252 -
RatioLiquidHydrogenR 253 -
RatioPollutedWaterR 254 -
NameHashR 268 -
RatioHydrazineR 283 -
RatioLiquidHydrazineR 284 -
RatioLiquidAlcoholR 285 -
RatioHeliumR 286 -
RatioLiquidSodiumChlorideR 287 -
RatioSilanolR 288 -
RatioLiquidSilanolR 289 -
RatioHydrochloricAcidR 290 -
RatioLiquidHydrochloricAcidR 291 -
RatioOzoneR 292 -
RatioLiquidOzoneR 293 -
RatioHydrogenOutputR 296 -
RatioLiquidHydrogenOutputR 300 -
RatioPollutedWaterOutputR 304 -
RatioHydrazineOutputR 308 -
RatioLiquidHydrazineOutputR 312 -
RatioLiquidAlcoholOutputR 316 -
RatioHeliumOutputR 320 -
RatioLiquidSodiumChlorideOutputR 324 -
RatioSilanolOutputR 328 -
RatioLiquidSilanolOutputR 332 -
RatioHydrochloricAcidOutputR 336 -
RatioLiquidHydrochloricAcidOutputR 340 -
RatioOzoneOutputR 344 -
RatioLiquidOzoneOutputR 348
Example: address by name
Reads Temperature, shows the value on the IC housing and writes Setting. Name the device with the labeller first; devices with the same name are addressed together.
# Small Tank address by name
define DEVICE 1013514688 # StructureTankSmall
define NAME HASH("Small Tank") # name in game (labeller)
define TARGET 50 # Setting target value (Setting)
alias value r0
start:
yield
lbn value DEVICE NAME Temperature 0 # 0 = average of all with this name
bnan value start # no device with this name
s db Setting value # show on the housing
sbn DEVICE NAME Setting TARGET # set value
j startAcademy: devices by name Academy: batch modes IC10 academy IC10 editor
Connections
- 1Data
- 2Gas pipe
Building and deconstruction
Grid: small grid (0.5 m) · mounting: free in the grid
- 1
Total material
Deconstruction returns
Material, fire and recycling
Heat exchange (factor × surface): radiation 0.03, convection 0.758, sun 1.52
Raw values from the game code (8)
Field names as in the game code, untranslated. Useful for mods and exact limits.
Tank._rocketInternalCellType | None |
DeviceInternal.volume | 6,000 |
DeviceInternal.ContentType | Gas |
DeviceAtmospherics.outputSetting | 50 |
DeviceAtmospherics.pressurePerTick | 1,010.3 |
DeviceAtmospherics.MinSetting | 0 |
DeviceAtmospherics.MaxSetting | 100 |
DeviceAtmospherics.ConnectionType | Exhaustive |
See also