stationeers.de Mod workshop · Dominik1199
DE Sign in
  1. Home
  2. Stationeers wiki
  3. Devices
  4. Pipe Analyzer

Devices

Pipe Analyzer

Rohr-Analysator

PrefabStructurePipeAnalysizer Hash435685051in the hash lookup
Pipes and atmosphere paintable Game 0.2.6428.27798

Overview

Pipe Analyzer (StructurePipeAnalysizer) in Stationeers: device, hash 435685051, 5 W. With build steps, 43 IC10 logic values and connection diagram.

The pipe analyzer is placed directly on a gas pipe and measures the whole network that pipe belongs to. In the game the prefab name really is spelled “Analysizer” – stick to that in IC10; the hash is 435685051.

Readable values include:

  • Pressure, Temperature and TotalMoles,
  • Volume – the volume of the network in litres,
  • the fraction of each gas, such as RatioOxygen or RatioMethane (that is Volatiles),
  • VolumeOfLiquid, in case liquid collects in the pipe.

You can write On and Lock. It has a shared port for power and data and needs 5 W.

Since tanks became part of the pipe network, it matters twice as much: an in-line tank such as the Small Tank has no logic of its own. The only way to see how full it is goes through an analyzer on the same network. With Volume and TotalMoles you can even fill by amount instead of pressure. An example: the network reports 6,100 litres. For 40,000 kPa at 20 °C you need n = 40,000 · 6,100 / (8.3144 · 293.15) ≈ 100,100 mol. That number stays right even if the gas warms up later.

One analyzer per network is enough. Give it a name and read it via lbn with batch mode 0. For room air there is the Gas Sensor, for liquid the Liquid Pipe Analyzer. A program for filling by moles is in Tanks and gas storage: sizes, insulation, safe filling.

IC10 and logic

43 logic values, 43 readable and 2 writable.

  • Power R 1
  • Error R 4
  • Pressure R 5
  • Temperature R 6
  • Lock RW 10
  • RatioOxygen R 14
  • RatioCarbonDioxide R 15
  • RatioNitrogen R 16
  • RatioPollutant R 17
  • RatioMethane R 18
  • RatioWater R 19
  • On RW 28
  • RequiredPower R 33
  • TotalMoles R 66
  • Volume R 67
  • RatioNitrousOxide R 83
  • PrefabHash R 84
  • Combustion R 98
  • RatioLiquidNitrogen R 177
  • VolumeOfLiquid R 182
  • RatioLiquidOxygen R 183
  • RatioLiquidMethane R 188
  • RatioSteam R 193
  • RatioLiquidCarbonDioxide R 199
  • RatioLiquidPollutant R 204
  • RatioLiquidNitrousOxide R 209
  • ReferenceId R 217
  • RatioHydrogen R 252
  • RatioLiquidHydrogen R 253
  • RatioPollutedWater R 254
  • NameHash R 268
  • NetworkFault R 273
  • RatioHydrazine R 283
  • RatioLiquidHydrazine R 284
  • RatioLiquidAlcohol R 285
  • RatioHelium R 286
  • RatioLiquidSodiumChloride R 287
  • RatioSilanol R 288
  • RatioLiquidSilanol R 289
  • RatioHydrochloricAcid R 290
  • RatioLiquidHydrochloricAcid R 291
  • RatioOzone R 292
  • RatioLiquidOzone R 293

Example: address by name

Reads Temperature, shows the value on the IC housing and writes On. Name the device with the labeller first; devices with the same name are addressed together.

# Pipe Analyzer address by name
define DEVICE 435685051  # StructurePipeAnalysizer
define NAME HASH("Pipe Analyzer")  # name in game (labeller)
define TARGET 1  # On 1 = on
alias value r0

start:
yield
lbn value DEVICE NAME Temperature 0  # 0 = average of all with this name
bnan value start  # no device with this name
s db Setting value  # show on the housing
sbn DEVICE NAME On TARGET  # set value
j start

Connections

1
Schematic: inputs left, outputs right, waste on top, power and data at the bottom. Position and spacing do not match the model.
  1. 1Power and data

Building and deconstruction

Grid: small grid (0.5 m) · mounting: free in the grid

  1. 1

    Place

    Take back with Hand Drill

Total material

Deconstruction returns

Built with: Kit (Pipe Analyzer)

Raw values from the game code (2)

Field names as in the game code, untranslated. Useful for mods and exact limits.

DevicePipeMounted.contentTypeGas
DevicePipeMounted.ConnectionTypeExhaustive

See also

Esc
↑ ↓ selectEnter open/ opens search anywhere