Overview
Large Tank (StructureTankBig) in Stationeers: device, hash -1606848156, 10 W, 50,000 L. With build steps, 73 IC10 logic values and connection diagram.
The large tank holds 50,000 litres, more than eight small tanks. It takes up 7 × 8 × 7 spots on the small grid, a good 3.5 × 4 × 3.5 m. In this old version it has a data port and gives Pressure, Temperature, TotalMoles and the gas fractions directly. Base draw is 10 W.
Since version 0.2.6143 the Kit (Tank) only builds in-line tanks. For the large tank you need five kits, and the result is the Large Tank with the same volume but no logic. The version on this page only exists in older saves. It equalises its inner volume with the pipe every tick, so pumps work more slowly on it than on an in-line tank.
For scale: at 10,000 kPa and 20 °C it holds n = 10,000 · 50,000 / (8.3144 · 293.15) ≈ 205,000 mol. A room of four cells needs about 1,330 mol at normal pressure – the tank could fill it a good 150 times.
Two things set it apart from the small tank: according to the game data it is flammable (flash point 373.15 K, autoignition 573.15 K), and it has a large surface through which it exchanges heat with its surroundings and warms up in the sun. Pressure rises with temperature. From a 60,795 kPa difference to the surroundings it takes damage, and once destroyed its whole contents end up in one cell.
If you want to avoid temperature swings, take the insulated version, see Tank Big (Insulated). Planning and safe filling are covered in Tanks and gas storage: sizes, insulation, safe filling.
IC10 and logic
73 logic values, 73 readable and 2 writable.
-
OpenRW 2 -
PressureR 5 -
TemperatureR 6 -
SettingRW 12 -
RatioOxygenR 14 -
RatioCarbonDioxideR 15 -
RatioNitrogenR 16 -
RatioPollutantR 17 -
RatioMethaneR 18 -
RatioWaterR 19 -
MaximumR 23 -
RatioR 24 -
TotalMolesR 66 -
VolumeR 67 -
RatioNitrousOxideR 83 -
PrefabHashR 84 -
CombustionR 98 -
PressureOutputR 126 -
TemperatureOutputR 127 -
RatioOxygenOutputR 128 -
RatioCarbonDioxideOutputR 129 -
RatioNitrogenOutputR 130 -
RatioPollutantOutputR 131 -
RatioMethaneOutputR 132 -
RatioWaterOutputR 133 -
RatioNitrousOxideOutputR 134 -
TotalMolesOutputR 135 -
CombustionOutputR 148 -
RatioLiquidNitrogenR 177 -
RatioLiquidNitrogenOutputR 180 -
VolumeOfLiquidR 182 -
RatioLiquidOxygenR 183 -
RatioLiquidOxygenOutputR 186 -
RatioLiquidMethaneR 188 -
RatioLiquidMethaneOutputR 191 -
RatioSteamR 193 -
RatioSteamOutputR 196 -
RatioLiquidCarbonDioxideR 199 -
RatioLiquidCarbonDioxideOutputR 202 -
RatioLiquidPollutantR 204 -
RatioLiquidPollutantOutputR 207 -
RatioLiquidNitrousOxideR 209 -
RatioLiquidNitrousOxideOutputR 212 -
ReferenceIdR 217 -
RatioHydrogenR 252 -
RatioLiquidHydrogenR 253 -
RatioPollutedWaterR 254 -
NameHashR 268 -
RatioHydrazineR 283 -
RatioLiquidHydrazineR 284 -
RatioLiquidAlcoholR 285 -
RatioHeliumR 286 -
RatioLiquidSodiumChlorideR 287 -
RatioSilanolR 288 -
RatioLiquidSilanolR 289 -
RatioHydrochloricAcidR 290 -
RatioLiquidHydrochloricAcidR 291 -
RatioOzoneR 292 -
RatioLiquidOzoneR 293 -
RatioHydrogenOutputR 296 -
RatioLiquidHydrogenOutputR 300 -
RatioPollutedWaterOutputR 304 -
RatioHydrazineOutputR 308 -
RatioLiquidHydrazineOutputR 312 -
RatioLiquidAlcoholOutputR 316 -
RatioHeliumOutputR 320 -
RatioLiquidSodiumChlorideOutputR 324 -
RatioSilanolOutputR 328 -
RatioLiquidSilanolOutputR 332 -
RatioHydrochloricAcidOutputR 336 -
RatioLiquidHydrochloricAcidOutputR 340 -
RatioOzoneOutputR 344 -
RatioLiquidOzoneOutputR 348
Example: address by name
Reads Temperature, shows the value on the IC housing and writes Setting. Name the device with the labeller first; devices with the same name are addressed together.
# Large Tank address by name
define DEVICE -1606848156 # StructureTankBig
define NAME HASH("Large Tank") # name in game (labeller)
define TARGET 5 # Setting target value (Setting)
alias value r0
start:
yield
lbn value DEVICE NAME Temperature 0 # 0 = average of all with this name
bnan value start # no device with this name
s db Setting value # show on the housing
sbn DEVICE NAME Setting TARGET # set value
j startAcademy: devices by name Academy: batch modes IC10 academy IC10 editor
Connections
- 1Data
- 2Gas pipe · input
Building and deconstruction
Grid: small grid (0.5 m) · mounting: free in the grid
- 1
Total material
- Kit (Tank) ×5
Deconstruction returns
- Kit (Tank) ×5
Material, fire and recycling
Flammable according to game data: flash point 373.2 K (100 °C); Autoignition 573.2 K (300 °C); burn time 5 s
Heat exchange (factor × surface): radiation 0.17, convection 4.24, sun 8.49
Raw values from the game code (8)
Field names as in the game code, untranslated. Useful for mods and exact limits.
Tank._rocketInternalCellType | None |
DeviceInternal.volume | 50,000 |
DeviceInternal.ContentType | Gas |
DeviceAtmospherics.outputSetting | 5 |
DeviceAtmospherics.pressurePerTick | 1,010.3 |
DeviceAtmospherics.MinSetting | 0 |
DeviceAtmospherics.MaxSetting | 100 |
DeviceAtmospherics.ConnectionType | Exhaustive |
See also
- Tanks and gas storage: sizes, insulation, safe fillingWhich stores exist, why tanks are now part of the pipe network, how to measure them, why you fill by moles instead of pressure and when insulation pays off – with an IC10 program.