Overview
Tank Small (Insulated) (StructureTankSmallInsulated) in Stationeers: device, hash 272136332, 10 W, 6,000 L. With build steps, 73 IC10 logic values and…
The insulated small tank holds 6,000 litres, just like the normal one. The difference lies in the heat values: radiation, convection and solar heating are all 0 in the game data. The gas in the tank keeps its temperature, whether outside there is sun, frost or 737 K Venus air.
A calculation shows why that matters. With the same amount of gas, pressure and temperature rise in the same ratio. A tank filled at 20 °C (293.15 K) to 20,000 kPa would, warmed to 737 K, sit at 20,000 · 737 / 293.15 ≈ 50,300 kPa – already above the stress limit of pipe networks (about 48,600 kPa). Insulated, that does not happen.
Good uses:
- keeping cold coolant cold,
- using hot gas as a heat store,
- storing supplies on hot or very cold worlds.
This version with a data port (10 W, readings such as Pressure, Temperature, TotalMoles) only exists in older saves. The Kit (Insulated Tank) now builds the Tank Small (Insulated) – part of the pipe network without logic of its own, measured with a Pipe Analyzer. Make sure the pipes to the tank are insulated as well, otherwise heat is lost there.
According to the game data the insulated tank is flammable (flash point 373.15 K). More on stores in Tanks and gas storage: sizes, insulation, safe filling.
IC10 and logic
73 logic values, 73 readable and 2 writable.
-
OpenRW 2 -
PressureR 5 -
TemperatureR 6 -
SettingRW 12 -
RatioOxygenR 14 -
RatioCarbonDioxideR 15 -
RatioNitrogenR 16 -
RatioPollutantR 17 -
RatioMethaneR 18 -
RatioWaterR 19 -
MaximumR 23 -
RatioR 24 -
TotalMolesR 66 -
VolumeR 67 -
RatioNitrousOxideR 83 -
PrefabHashR 84 -
CombustionR 98 -
PressureOutputR 126 -
TemperatureOutputR 127 -
RatioOxygenOutputR 128 -
RatioCarbonDioxideOutputR 129 -
RatioNitrogenOutputR 130 -
RatioPollutantOutputR 131 -
RatioMethaneOutputR 132 -
RatioWaterOutputR 133 -
RatioNitrousOxideOutputR 134 -
TotalMolesOutputR 135 -
CombustionOutputR 148 -
RatioLiquidNitrogenR 177 -
RatioLiquidNitrogenOutputR 180 -
VolumeOfLiquidR 182 -
RatioLiquidOxygenR 183 -
RatioLiquidOxygenOutputR 186 -
RatioLiquidMethaneR 188 -
RatioLiquidMethaneOutputR 191 -
RatioSteamR 193 -
RatioSteamOutputR 196 -
RatioLiquidCarbonDioxideR 199 -
RatioLiquidCarbonDioxideOutputR 202 -
RatioLiquidPollutantR 204 -
RatioLiquidPollutantOutputR 207 -
RatioLiquidNitrousOxideR 209 -
RatioLiquidNitrousOxideOutputR 212 -
ReferenceIdR 217 -
RatioHydrogenR 252 -
RatioLiquidHydrogenR 253 -
RatioPollutedWaterR 254 -
NameHashR 268 -
RatioHydrazineR 283 -
RatioLiquidHydrazineR 284 -
RatioLiquidAlcoholR 285 -
RatioHeliumR 286 -
RatioLiquidSodiumChlorideR 287 -
RatioSilanolR 288 -
RatioLiquidSilanolR 289 -
RatioHydrochloricAcidR 290 -
RatioLiquidHydrochloricAcidR 291 -
RatioOzoneR 292 -
RatioLiquidOzoneR 293 -
RatioHydrogenOutputR 296 -
RatioLiquidHydrogenOutputR 300 -
RatioPollutedWaterOutputR 304 -
RatioHydrazineOutputR 308 -
RatioLiquidHydrazineOutputR 312 -
RatioLiquidAlcoholOutputR 316 -
RatioHeliumOutputR 320 -
RatioLiquidSodiumChlorideOutputR 324 -
RatioSilanolOutputR 328 -
RatioLiquidSilanolOutputR 332 -
RatioHydrochloricAcidOutputR 336 -
RatioLiquidHydrochloricAcidOutputR 340 -
RatioOzoneOutputR 344 -
RatioLiquidOzoneOutputR 348
Example: address by name
Reads Temperature, shows the value on the IC housing and writes Setting. Name the device with the labeller first; devices with the same name are addressed together.
# Tank Small (Insulated) address by name
define DEVICE 272136332 # StructureTankSmallInsulated
define NAME HASH("Tank Small (Insulated)") # name in game (labeller)
define TARGET 5 # Setting target value (Setting)
alias value r0
start:
yield
lbn value DEVICE NAME Temperature 0 # 0 = average of all with this name
bnan value start # no device with this name
s db Setting value # show on the housing
sbn DEVICE NAME Setting TARGET # set value
j startAcademy: devices by name Academy: batch modes IC10 academy IC10 editor
Connections
- 1Data
- 2Gas pipe · input
Building and deconstruction
Grid: small grid (0.5 m) · mounting: free in the grid
- 1
Total material
Deconstruction returns
Material, fire and recycling
Flammable according to game data: flash point 373.2 K (100 °C); Autoignition 573.2 K (300 °C); burn time 14.23 s
Heat exchange (factor × surface): radiation 0, convection 0, sun 0
Raw values from the game code (8)
Field names as in the game code, untranslated. Useful for mods and exact limits.
Tank._rocketInternalCellType | None |
DeviceInternal.volume | 6,000 |
DeviceInternal.ContentType | Gas |
DeviceAtmospherics.outputSetting | 5 |
DeviceAtmospherics.pressurePerTick | 1,010.3 |
DeviceAtmospherics.MinSetting | 0 |
DeviceAtmospherics.MaxSetting | 100 |
DeviceAtmospherics.ConnectionType | FaceWallZY |
See also
- Tanks and gas storage: sizes, insulation, safe fillingWhich stores exist, why tanks are now part of the pipe network, how to measure them, why you fill by moles instead of pressure and when insulation pays off – with an IC10 program.