What you learn today
- lerp between two values
- Turn percent into device values
- lerp clamps the ratio
The warmer the server room, the faster the cooling pump should run: 2 litres at 22 °C, 10 at 30 °C. Smoothly in between. That is a straight line between two points – exactly what lerp is for.
lerp
lerp r0 a b t # r0 = a + (b - a) * t
| t | Result |
|---|---|
| 0 | a |
| 0.5 | exactly in the middle |
| 1 | b |
lerp r0 2 10 0.25 gives 4: a quarter of the way from 2 to 10.
lerp clamps the ratio
The special thing: t is clamped to 0 to 1 first. At t = 2 the result is b, not double. At t = −1 the result is a. That saves you the clamp – the result always lies between a and b.
lerp r0 0 100 2 # 100, not 200
From reading to ratio
You compute the ratio from the reading: (value − start) / (end − start).
sub t temp LOWER # LOWER = 295.15, 22 C
div t t 8 # 8 degrees up to 30 C
lerp flow 2 10 t # 2 to 10 litres
Below 22 °C t is negative, lerp turns it into 2. Above 30 °C t is greater than 1, lerp turns it into 10. That way a pump never runs below its minimum flow and never above its maximum.
Percent into device values
A share from 0 to 1 already is a finished ratio. A battery with Ratio 0.3 converts directly: lerp r1 0 10 ratio gives 3. Percent values from 0 to 100 you divide by 100 first.
Falling curves work too: lerp flow 10 2 t gives 10 at t = 0 and 2 at t = 1 – the fuller a tank, the slower the filling pump.
If the sensor is missing, t is NaN, and lerp returns NaN as well. The safe direction depends on the device: a cooling pump would rather run at full on failure, a filling pump would rather stand still. You decide it with snan and select.
Diagram
Exercise
Task
A sliding cooling pump. On the network: gas sensor “Serverraum”, volume pump “Kuehlpumpe”, LED display “Pumpenlast”.
- Ratio t = (temperature − 22 °C) / 8 K.
- Pump
Setting=lerpfrom 2 to 10 with t;Onalways 1. - “Pumpenlast” shows t, limited to 0 to 1, in Percent mode.
- If the sensor fails, the pump runs at full (10) and the display shows 100 %.
Hints
Hint 1
t: sub t temp LOWER, then div t t SPAN.
Hint 2
Replace NaN with 1 first – then the pump runs at full on failure.
Hint 3
lerp flow MINFLOW MAXFLOW t clamps t by itself; for the display you still need a clamp.
Quiz
4 questions. You pass from 60 % – the server does the grading.
Complete the day
- Passed the simulator exercise
- Passed the quiz with at least 60 %
Without an account progress is saved in this browser only.