stationeers.de Mod workshop · Dominik1199
DE Sign in
  1. Home
  2. Stationeers wiki
  3. Devices
  4. Powered Vent

Devices

Powered Vent

PrefabStructurePoweredVent Hash938836756in the hash lookup
Pipes and atmosphere paintable Game 0.2.6428.27798

Overview

Powered Vent (StructurePoweredVent) in Stationeers: device, hash 938836756, 250 W. With build steps, 42 IC10 logic values and connection diagram.

The powered vent is the big brother of the Active Vent. It takes up 2 × 2 spots on the small grid, an area of 1 × 1 m, and moves up to 20 kPa per tick – twice as much as the active vent. In a cell of 8,000 litres at 20 °C that is about 66 mol per tick.

It has two modes: 0 Outward blows gas from the pipe into the room, 1 Inward sucks it from the room into the pipe. You set the target pressure for the room with PressureExternal. Unlike the active vent it has no separate target for the pipe (PressureInternal) and no Setting. On top of that come On, Lock and readings for the gas in the pipe (…Output).

Power, data and pipe each have their own port. Base draw is 250 W.

It is built in three steps:

  1. place the Kit (Powered Vent),
  2. fit two Kit (Pipe) with the screwdriver,
  3. attach two plastic sheets with the welding torch.

A calculation shows what it is good for: a room of four cells needs about 1,330 mol at normal pressure. At 66 mol per tick it would be filled after roughly 20 ticks, i.e. 10 seconds – provided the pipe network keeps up. That is ideal for airlocks and halls. Mind the walls, though: an iron wall only holds a 200 kPa difference. So let a chip with a Gas Sensor control the vent, see Building an airlock: layout, control, common mistakes.

IC10 and logic

42 logic values, 42 readable and 4 writable.

  • Power R 1
  • Mode RW 3
  • Error R 4
  • PressureExternal RW 7
  • Lock RW 10
  • On RW 28
  • RequiredPower R 33
  • PrefabHash R 84
  • PressureOutput R 126
  • TemperatureOutput R 127
  • RatioOxygenOutput R 128
  • RatioCarbonDioxideOutput R 129
  • RatioNitrogenOutput R 130
  • RatioPollutantOutput R 131
  • RatioMethaneOutput R 132
  • RatioWaterOutput R 133
  • RatioNitrousOxideOutput R 134
  • TotalMolesOutput R 135
  • CombustionOutput R 148
  • RatioLiquidNitrogenOutput R 180
  • RatioLiquidOxygenOutput R 186
  • RatioLiquidMethaneOutput R 191
  • RatioSteamOutput R 196
  • RatioLiquidCarbonDioxideOutput R 202
  • RatioLiquidPollutantOutput R 207
  • RatioLiquidNitrousOxideOutput R 212
  • ReferenceId R 217
  • NameHash R 268
  • RatioHydrogenOutput R 296
  • RatioLiquidHydrogenOutput R 300
  • RatioPollutedWaterOutput R 304
  • RatioHydrazineOutput R 308
  • RatioLiquidHydrazineOutput R 312
  • RatioLiquidAlcoholOutput R 316
  • RatioHeliumOutput R 320
  • RatioLiquidSodiumChlorideOutput R 324
  • RatioSilanolOutput R 328
  • RatioLiquidSilanolOutput R 332
  • RatioHydrochloricAcidOutput R 336
  • RatioLiquidHydrochloricAcidOutput R 340
  • RatioOzoneOutput R 344
  • RatioLiquidOzoneOutput R 348

Example: address by name

Reads On, shows the value on the IC housing and writes Mode. Name the device with the labeller first; devices with the same name are addressed together.

# Powered Vent address by name
define DEVICE 938836756  # StructurePoweredVent
define NAME HASH("Powered Vent")  # name in game (labeller)
define TARGET 0  # Mode mode 0
alias value r0

start:
yield
lbn value DEVICE NAME On 0  # 0 = average of all with this name
bnan value start  # no device with this name
s db Setting value  # show on the housing
sbn DEVICE NAME Mode TARGET  # set value
j start

Connections

2Gas13
Schematic: inputs left, outputs right, waste on top, power and data at the bottom. Position and spacing do not match the model.
  1. 1Data
  2. 2Gas pipe · output
  3. 3Power

Slots and modes

Modes: 0 = Outward, 1 = Inward

Building and deconstruction

Grid: small grid (0.5 m) · mounting: on wall or floor

  1. 1

    Place

    Take back with Hand Drill

  2. 2

    Build stage 2

    Take back with Wrench

  3. 3

    Build stage 3

    Take back with Angle Grinder

Deconstruction returns

Built with: Kit (Powered Vent)

Raw values from the game code (6)

Field names as in the game code, untranslated. Useful for mods and exact limits.

PoweredVentMultiGrid.gridMixingDepth4
DeviceAtmospherics.outputSetting20,000
DeviceAtmospherics.pressurePerTick20
DeviceAtmospherics.MinSetting0
DeviceAtmospherics.MaxSetting50,000
DeviceAtmospherics.ConnectionTypeFlatExhaustive

See also

Esc
↑ ↓ selectEnter open/ opens search anywhere