Overview
Powered Vent (StructurePoweredVent) in Stationeers: device, hash 938836756, 250 W. With build steps, 42 IC10 logic values and connection diagram.
The powered vent is the big brother of the Active Vent. It takes up 2 × 2 spots on the small grid, an area of 1 × 1 m, and moves up to 20 kPa per tick – twice as much as the active vent. In a cell of 8,000 litres at 20 °C that is about 66 mol per tick.
It has two modes: 0 Outward blows gas from the pipe into the room, 1 Inward sucks it from the room into the pipe. You set the target pressure for the room with PressureExternal. Unlike the active vent it has no separate target for the pipe (PressureInternal) and no Setting. On top of that come On, Lock and readings for the gas in the pipe (…Output).
Power, data and pipe each have their own port. Base draw is 250 W.
It is built in three steps:
- place the Kit (Powered Vent),
- fit two Kit (Pipe) with the screwdriver,
- attach two plastic sheets with the welding torch.
A calculation shows what it is good for: a room of four cells needs about 1,330 mol at normal pressure. At 66 mol per tick it would be filled after roughly 20 ticks, i.e. 10 seconds – provided the pipe network keeps up. That is ideal for airlocks and halls. Mind the walls, though: an iron wall only holds a 200 kPa difference. So let a chip with a Gas Sensor control the vent, see Building an airlock: layout, control, common mistakes.
IC10 and logic
42 logic values, 42 readable and 4 writable.
-
PowerR 1 -
ModeRW 3 -
ErrorR 4 -
PressureExternalRW 7 -
LockRW 10 -
OnRW 28 -
RequiredPowerR 33 -
PrefabHashR 84 -
PressureOutputR 126 -
TemperatureOutputR 127 -
RatioOxygenOutputR 128 -
RatioCarbonDioxideOutputR 129 -
RatioNitrogenOutputR 130 -
RatioPollutantOutputR 131 -
RatioMethaneOutputR 132 -
RatioWaterOutputR 133 -
RatioNitrousOxideOutputR 134 -
TotalMolesOutputR 135 -
CombustionOutputR 148 -
RatioLiquidNitrogenOutputR 180 -
RatioLiquidOxygenOutputR 186 -
RatioLiquidMethaneOutputR 191 -
RatioSteamOutputR 196 -
RatioLiquidCarbonDioxideOutputR 202 -
RatioLiquidPollutantOutputR 207 -
RatioLiquidNitrousOxideOutputR 212 -
ReferenceIdR 217 -
NameHashR 268 -
RatioHydrogenOutputR 296 -
RatioLiquidHydrogenOutputR 300 -
RatioPollutedWaterOutputR 304 -
RatioHydrazineOutputR 308 -
RatioLiquidHydrazineOutputR 312 -
RatioLiquidAlcoholOutputR 316 -
RatioHeliumOutputR 320 -
RatioLiquidSodiumChlorideOutputR 324 -
RatioSilanolOutputR 328 -
RatioLiquidSilanolOutputR 332 -
RatioHydrochloricAcidOutputR 336 -
RatioLiquidHydrochloricAcidOutputR 340 -
RatioOzoneOutputR 344 -
RatioLiquidOzoneOutputR 348
Example: address by name
Reads On, shows the value on the IC housing and writes Mode. Name the device with the labeller first; devices with the same name are addressed together.
# Powered Vent address by name
define DEVICE 938836756 # StructurePoweredVent
define NAME HASH("Powered Vent") # name in game (labeller)
define TARGET 0 # Mode mode 0
alias value r0
start:
yield
lbn value DEVICE NAME On 0 # 0 = average of all with this name
bnan value start # no device with this name
s db Setting value # show on the housing
sbn DEVICE NAME Mode TARGET # set value
j startAcademy: devices by name Academy: batch modes IC10 academy IC10 editor
Connections
- 1Data
- 2Gas pipe · output
- 3Power
Slots and modes
Modes: 0 = Outward, 1 = Inward
Building and deconstruction
Grid: small grid (0.5 m) · mounting: on wall or floor
- 1
- 2
- 3
Total material
Deconstruction returns
Built with: Kit (Powered Vent)
Raw values from the game code (6)
Field names as in the game code, untranslated. Useful for mods and exact limits.
PoweredVentMultiGrid.gridMixingDepth | 4 |
DeviceAtmospherics.outputSetting | 20,000 |
DeviceAtmospherics.pressurePerTick | 20 |
DeviceAtmospherics.MinSetting | 0 |
DeviceAtmospherics.MaxSetting | 50,000 |
DeviceAtmospherics.ConnectionType | FlatExhaustive |
See also