Overview
Tank Big (Insulated) (StructureTankBigInsulated) in Stationeers: device, hash 1280378227, 10 W, 50,000 L. With build steps, 73 IC10 logic values and…
The large insulated tank combines the size of the Large Tank – 50,000 litres on 7 × 8 × 7 spots – with the insulation of the small insulated tank: radiation, convection and solar heating are set to 0 in the game data. At this size that really pays off, because the normal large tank has a lot of surface and reacts strongly to sun and cold.
This version with a data port and readings (Pressure, Temperature, TotalMoles, gas fractions, 10 W) only exists in older saves. Five Kit (Insulated Tank) now build the Tank Big (Insulated): same volume, part of the pipe network, no logic of its own. You then measure it with a Pipe Analyzer on the same network.
A calculation for a cold store: 50,000 litres of nitrogen at 5,000 kPa and −50 °C (223 K) are n = 5,000 · 50,000 / (8.3144 · 223) ≈ 134,800 mol. At 20.6 J per mole and kelvin the gas stores about 2.8 MJ per kelvin. A wall cooler pushing about 2 kW of heat into its pipe would have to run for over 23 minutes to warm this store by a single kelvin.
This tank is also flammable according to the game data (flash point 373.15 K). From a 60,795 kPa difference to the surroundings it takes damage, and if it is destroyed the whole contents end up in one cell. More on planning in Tanks and gas storage: sizes, insulation, safe filling.
IC10 and logic
73 logic values, 73 readable and 2 writable.
-
OpenRW 2 -
PressureR 5 -
TemperatureR 6 -
SettingRW 12 -
RatioOxygenR 14 -
RatioCarbonDioxideR 15 -
RatioNitrogenR 16 -
RatioPollutantR 17 -
RatioMethaneR 18 -
RatioWaterR 19 -
MaximumR 23 -
RatioR 24 -
TotalMolesR 66 -
VolumeR 67 -
RatioNitrousOxideR 83 -
PrefabHashR 84 -
CombustionR 98 -
PressureOutputR 126 -
TemperatureOutputR 127 -
RatioOxygenOutputR 128 -
RatioCarbonDioxideOutputR 129 -
RatioNitrogenOutputR 130 -
RatioPollutantOutputR 131 -
RatioMethaneOutputR 132 -
RatioWaterOutputR 133 -
RatioNitrousOxideOutputR 134 -
TotalMolesOutputR 135 -
CombustionOutputR 148 -
RatioLiquidNitrogenR 177 -
RatioLiquidNitrogenOutputR 180 -
VolumeOfLiquidR 182 -
RatioLiquidOxygenR 183 -
RatioLiquidOxygenOutputR 186 -
RatioLiquidMethaneR 188 -
RatioLiquidMethaneOutputR 191 -
RatioSteamR 193 -
RatioSteamOutputR 196 -
RatioLiquidCarbonDioxideR 199 -
RatioLiquidCarbonDioxideOutputR 202 -
RatioLiquidPollutantR 204 -
RatioLiquidPollutantOutputR 207 -
RatioLiquidNitrousOxideR 209 -
RatioLiquidNitrousOxideOutputR 212 -
ReferenceIdR 217 -
RatioHydrogenR 252 -
RatioLiquidHydrogenR 253 -
RatioPollutedWaterR 254 -
NameHashR 268 -
RatioHydrazineR 283 -
RatioLiquidHydrazineR 284 -
RatioLiquidAlcoholR 285 -
RatioHeliumR 286 -
RatioLiquidSodiumChlorideR 287 -
RatioSilanolR 288 -
RatioLiquidSilanolR 289 -
RatioHydrochloricAcidR 290 -
RatioLiquidHydrochloricAcidR 291 -
RatioOzoneR 292 -
RatioLiquidOzoneR 293 -
RatioHydrogenOutputR 296 -
RatioLiquidHydrogenOutputR 300 -
RatioPollutedWaterOutputR 304 -
RatioHydrazineOutputR 308 -
RatioLiquidHydrazineOutputR 312 -
RatioLiquidAlcoholOutputR 316 -
RatioHeliumOutputR 320 -
RatioLiquidSodiumChlorideOutputR 324 -
RatioSilanolOutputR 328 -
RatioLiquidSilanolOutputR 332 -
RatioHydrochloricAcidOutputR 336 -
RatioLiquidHydrochloricAcidOutputR 340 -
RatioOzoneOutputR 344 -
RatioLiquidOzoneOutputR 348
Example: address by name
Reads Temperature, shows the value on the IC housing and writes Setting. Name the device with the labeller first; devices with the same name are addressed together.
# Tank Big (Insulated) address by name
define DEVICE 1280378227 # StructureTankBigInsulated
define NAME HASH("Tank Big (Insulated)") # name in game (labeller)
define TARGET 5 # Setting target value (Setting)
alias value r0
start:
yield
lbn value DEVICE NAME Temperature 0 # 0 = average of all with this name
bnan value start # no device with this name
s db Setting value # show on the housing
sbn DEVICE NAME Setting TARGET # set value
j startAcademy: devices by name Academy: batch modes IC10 academy IC10 editor
Connections
- 1Data
- 2Gas pipe · input
Building and deconstruction
Grid: small grid (0.5 m) · mounting: free in the grid
- 1
Total material
Deconstruction returns
Material, fire and recycling
Flammable according to game data: flash point 373.2 K (100 °C); Autoignition 573.2 K (300 °C); burn time 31.83 s
Heat exchange (factor × surface): radiation 0, convection 0, sun 0
Raw values from the game code (8)
Field names as in the game code, untranslated. Useful for mods and exact limits.
Tank._rocketInternalCellType | None |
DeviceInternal.volume | 50,000 |
DeviceInternal.ContentType | Gas |
DeviceAtmospherics.outputSetting | 5 |
DeviceAtmospherics.pressurePerTick | 1,010.3 |
DeviceAtmospherics.MinSetting | 0 |
DeviceAtmospherics.MaxSetting | 100 |
DeviceAtmospherics.ConnectionType | FaceWallZY |
See also