stationeers.de Mod workshop · Dominik1199
DE Sign in
  1. Home
  2. Stationeers wiki
  3. Devices
  4. Tank Big (Insulated)

Devices

Tank Big (Insulated)

Tank groß (isoliert)

PrefabStructureTankBigInsulated Hash1280378227in the hash lookup
Pipes and atmosphere not in the Stationpedia paintable Game 0.2.6428.27798

Overview

Tank Big (Insulated) (StructureTankBigInsulated) in Stationeers: device, hash 1280378227, 10 W, 50,000 L. With build steps, 73 IC10 logic values and…

The large insulated tank combines the size of the Large Tank – 50,000 litres on 7 × 8 × 7 spots – with the insulation of the small insulated tank: radiation, convection and solar heating are set to 0 in the game data. At this size that really pays off, because the normal large tank has a lot of surface and reacts strongly to sun and cold.

This version with a data port and readings (Pressure, Temperature, TotalMoles, gas fractions, 10 W) only exists in older saves. Five Kit (Insulated Tank) now build the Tank Big (Insulated): same volume, part of the pipe network, no logic of its own. You then measure it with a Pipe Analyzer on the same network.

A calculation for a cold store: 50,000 litres of nitrogen at 5,000 kPa and −50 °C (223 K) are n = 5,000 · 50,000 / (8.3144 · 223) ≈ 134,800 mol. At 20.6 J per mole and kelvin the gas stores about 2.8 MJ per kelvin. A wall cooler pushing about 2 kW of heat into its pipe would have to run for over 23 minutes to warm this store by a single kelvin.

This tank is also flammable according to the game data (flash point 373.15 K). From a 60,795 kPa difference to the surroundings it takes damage, and if it is destroyed the whole contents end up in one cell. More on planning in Tanks and gas storage: sizes, insulation, safe filling.

IC10 and logic

73 logic values, 73 readable and 2 writable.

  • Open RW 2
  • Pressure R 5
  • Temperature R 6
  • Setting RW 12
  • RatioOxygen R 14
  • RatioCarbonDioxide R 15
  • RatioNitrogen R 16
  • RatioPollutant R 17
  • RatioMethane R 18
  • RatioWater R 19
  • Maximum R 23
  • Ratio R 24
  • TotalMoles R 66
  • Volume R 67
  • RatioNitrousOxide R 83
  • PrefabHash R 84
  • Combustion R 98
  • PressureOutput R 126
  • TemperatureOutput R 127
  • RatioOxygenOutput R 128
  • RatioCarbonDioxideOutput R 129
  • RatioNitrogenOutput R 130
  • RatioPollutantOutput R 131
  • RatioMethaneOutput R 132
  • RatioWaterOutput R 133
  • RatioNitrousOxideOutput R 134
  • TotalMolesOutput R 135
  • CombustionOutput R 148
  • RatioLiquidNitrogen R 177
  • RatioLiquidNitrogenOutput R 180
  • VolumeOfLiquid R 182
  • RatioLiquidOxygen R 183
  • RatioLiquidOxygenOutput R 186
  • RatioLiquidMethane R 188
  • RatioLiquidMethaneOutput R 191
  • RatioSteam R 193
  • RatioSteamOutput R 196
  • RatioLiquidCarbonDioxide R 199
  • RatioLiquidCarbonDioxideOutput R 202
  • RatioLiquidPollutant R 204
  • RatioLiquidPollutantOutput R 207
  • RatioLiquidNitrousOxide R 209
  • RatioLiquidNitrousOxideOutput R 212
  • ReferenceId R 217
  • RatioHydrogen R 252
  • RatioLiquidHydrogen R 253
  • RatioPollutedWater R 254
  • NameHash R 268
  • RatioHydrazine R 283
  • RatioLiquidHydrazine R 284
  • RatioLiquidAlcohol R 285
  • RatioHelium R 286
  • RatioLiquidSodiumChloride R 287
  • RatioSilanol R 288
  • RatioLiquidSilanol R 289
  • RatioHydrochloricAcid R 290
  • RatioLiquidHydrochloricAcid R 291
  • RatioOzone R 292
  • RatioLiquidOzone R 293
  • RatioHydrogenOutput R 296
  • RatioLiquidHydrogenOutput R 300
  • RatioPollutedWaterOutput R 304
  • RatioHydrazineOutput R 308
  • RatioLiquidHydrazineOutput R 312
  • RatioLiquidAlcoholOutput R 316
  • RatioHeliumOutput R 320
  • RatioLiquidSodiumChlorideOutput R 324
  • RatioSilanolOutput R 328
  • RatioLiquidSilanolOutput R 332
  • RatioHydrochloricAcidOutput R 336
  • RatioLiquidHydrochloricAcidOutput R 340
  • RatioOzoneOutput R 344
  • RatioLiquidOzoneOutput R 348

Example: address by name

Reads Temperature, shows the value on the IC housing and writes Setting. Name the device with the labeller first; devices with the same name are addressed together.

# Tank Big (Insulated) address by name
define DEVICE 1280378227  # StructureTankBigInsulated
define NAME HASH("Tank Big (Insulated)")  # name in game (labeller)
define TARGET 5  # Setting target value (Setting)
alias value r0

start:
yield
lbn value DEVICE NAME Temperature 0  # 0 = average of all with this name
bnan value start  # no device with this name
s db Setting value  # show on the housing
sbn DEVICE NAME Setting TARGET  # set value
j start

Connections

2Gas1
Schematic: inputs left, outputs right, waste on top, power and data at the bottom. Position and spacing do not match the model.
  1. 1Data
  2. 2Gas pipe · input

Building and deconstruction

Grid: small grid (0.5 m) · mounting: free in the grid

  1. 1

    Place

    Take back with Hand Drill

Total material

Deconstruction returns

Material, fire and recycling

Flammable according to game data: flash point 373.2 K (100 °C); Autoignition 573.2 K (300 °C); burn time 31.83 s

Heat exchange (factor × surface): radiation 0, convection 0, sun 0

Raw values from the game code (8)

Field names as in the game code, untranslated. Useful for mods and exact limits.

Tank._rocketInternalCellTypeNone
DeviceInternal.volume50,000
DeviceInternal.ContentTypeGas
DeviceAtmospherics.outputSetting5
DeviceAtmospherics.pressurePerTick1,010.3
DeviceAtmospherics.MinSetting0
DeviceAtmospherics.MaxSetting100
DeviceAtmospherics.ConnectionTypeFaceWallZY

See also

Esc
↑ ↓ selectEnter open/ opens search anywhere