PrefabStructureAirConditioner Hash-2087593337in the hash lookup
Power paintable Game 0.2.6428.27798

Overview

Air Conditioner (StructureAirConditioner) in Stationeers: device, hash -2087593337, 10 W. With build steps, 112 IC10 logic values and connection diagram.

The air conditioner has three pipe ports: input, output and waste. Gas from the input is brought to the target and released at the output; the waste network gets the opposite. It only works on gas in pipes – it does not cool room air directly.

Setting is the target temperature in kelvin, from 3.15 to 1,272.15 K. The value also decides the direction: if it is above the input temperature, the device heats. For 18 °C you set 291.15.

Three logic values show how well it works: TemperatureDifferentialEfficiency drops the further input and waste are apart, OperationalTemperatureEfficiency when one side is very hot or very cold, and PressureEfficiency when pipe pressure is low.

All three pipes must be connected. If one is missing, it does not work. Base draw is 10 W, considerably more while running. It is built like the filtration unit: atmospherics kit, two pipe kits, two cable coils with the screwdriver.

IC10 and logic

112 logic values, 112 readable and 5 writable.

  • Power R 1
  • Open RW 2
  • Mode RW 3
  • Error R 4
  • Lock RW 10
  • Setting RW 12
  • Maximum R 23
  • Ratio R 24
  • On RW 28
  • RequiredPower R 33
  • PrefabHash R 84
  • PressureInput R 106
  • TemperatureInput R 107
  • RatioOxygenInput R 108
  • RatioCarbonDioxideInput R 109
  • RatioNitrogenInput R 110
  • RatioPollutantInput R 111
  • RatioMethaneInput R 112
  • RatioWaterInput R 113
  • RatioNitrousOxideInput R 114
  • TotalMolesInput R 115
  • PressureOutput R 126
  • TemperatureOutput R 127
  • RatioOxygenOutput R 128
  • RatioCarbonDioxideOutput R 129
  • RatioNitrogenOutput R 130
  • RatioPollutantOutput R 131
  • RatioMethaneOutput R 132
  • RatioWaterOutput R 133
  • RatioNitrousOxideOutput R 134
  • TotalMolesOutput R 135
  • PressureOutput2 R 136
  • TemperatureOutput2 R 137
  • RatioOxygenOutput2 R 138
  • RatioCarbonDioxideOutput2 R 139
  • RatioNitrogenOutput2 R 140
  • RatioPollutantOutput2 R 141
  • RatioMethaneOutput2 R 142
  • RatioWaterOutput2 R 143
  • RatioNitrousOxideOutput2 R 144
  • TotalMolesOutput2 R 145
  • CombustionInput R 146
  • CombustionOutput R 148
  • CombustionOutput2 R 149
  • OperationalTemperatureEfficiency R 150
  • TemperatureDifferentialEfficiency R 151
  • PressureEfficiency R 152
  • RatioLiquidNitrogenInput R 178
  • RatioLiquidNitrogenOutput R 180
  • RatioLiquidNitrogenOutput2 R 181
  • RatioLiquidOxygenInput R 184
  • RatioLiquidOxygenOutput R 186
  • RatioLiquidOxygenOutput2 R 187
  • RatioLiquidMethaneInput R 189
  • RatioLiquidMethaneOutput R 191
  • RatioLiquidMethaneOutput2 R 192
  • RatioSteamInput R 194
  • RatioSteamOutput R 196
  • RatioSteamOutput2 R 197
  • RatioLiquidCarbonDioxideInput R 200
  • RatioLiquidCarbonDioxideOutput R 202
  • RatioLiquidCarbonDioxideOutput2 R 203
  • RatioLiquidPollutantInput R 205
  • RatioLiquidPollutantOutput R 207
  • RatioLiquidPollutantOutput2 R 208
  • RatioLiquidNitrousOxideInput R 210
  • RatioLiquidNitrousOxideOutput R 212
  • RatioLiquidNitrousOxideOutput2 R 213
  • ReferenceId R 217
  • NameHash R 268
  • RatioHydrogenInput R 294
  • RatioHydrogenOutput R 296
  • RatioHydrogenOutput2 R 297
  • RatioLiquidHydrogenInput R 298
  • RatioLiquidHydrogenOutput R 300
  • RatioLiquidHydrogenOutput2 R 301
  • RatioPollutedWaterInput R 302
  • RatioPollutedWaterOutput R 304
  • RatioPollutedWaterOutput2 R 305
  • RatioHydrazineInput R 306
  • RatioHydrazineOutput R 308
  • RatioHydrazineOutput2 R 309
  • RatioLiquidHydrazineInput R 310
  • RatioLiquidHydrazineOutput R 312
  • RatioLiquidHydrazineOutput2 R 313
  • RatioLiquidAlcoholInput R 314
  • RatioLiquidAlcoholOutput R 316
  • RatioLiquidAlcoholOutput2 R 317
  • RatioHeliumInput R 318
  • RatioHeliumOutput R 320
  • RatioHeliumOutput2 R 321
  • RatioLiquidSodiumChlorideInput R 322
  • RatioLiquidSodiumChlorideOutput R 324
  • RatioLiquidSodiumChlorideOutput2 R 325
  • RatioSilanolInput R 326
  • RatioSilanolOutput R 328
  • RatioSilanolOutput2 R 329
  • RatioLiquidSilanolInput R 330
  • RatioLiquidSilanolOutput R 332
  • RatioLiquidSilanolOutput2 R 333
  • RatioHydrochloricAcidInput R 334
  • RatioHydrochloricAcidOutput R 336
  • RatioHydrochloricAcidOutput2 R 337
  • RatioLiquidHydrochloricAcidInput R 338
  • RatioLiquidHydrochloricAcidOutput R 340
  • RatioLiquidHydrochloricAcidOutput2 R 341
  • RatioOzoneInput R 342
  • RatioOzoneOutput R 344
  • RatioOzoneOutput2 R 345
  • RatioLiquidOzoneInput R 346
  • RatioLiquidOzoneOutput R 348
  • RatioLiquidOzoneOutput2 R 349

Values per slot (slot logic)

Slot valuereadable in slotwritable in slotNumber
Occupied0–1
OccupantHash0–2
Quantity0–3
Damage0–4
Class0–12
MaxQuantity0–15
PrefabHash0–17
SortingClass0–24
ReferenceId0–26
FreeSlots0–31
TotalSlots0–32

Example: address by name

Reads Setting, shows the value on the IC housing and writes On. Name the device with the labeller first; devices with the same name are addressed together.

# Air Conditioner address by name
define DEVICE -2087593337  # StructureAirConditioner
define NAME HASH("Air Conditioner")  # name in game (labeller)
define TARGET 1  # On 1 = on
alias value r0

start:
yield
lbn value DEVICE NAME Setting 0  # 0 = average of all with this name
bnan value start  # no device with this name
s db Setting value  # show on the housing
sbn DEVICE NAME On TARGET  # set value
j start

Connections

2Gas3Gas415
Schematic: inputs left, outputs right, waste on top, power and data at the bottom. Position and spacing do not match the model.
  1. 1Data
  2. 2Gas pipe · input
  3. 3Gas pipe · output
  4. 4Gas pipe · waste
  5. 5Power

Slots and modes

#SlotTakes
0Programmable ChipProgrammableChip

Modes: 0 = Idle, 1 = Active

Building and deconstruction

Grid: small grid (0.5 m) · mounting: free in the grid

  1. 1

    Place

    Take back with Hand Drill

  2. 2

    Build stage 2

    Take back with Wrench

  3. 3

    Build stage 3

    Take back with Hand Drill

Deconstruction returns

Built with: Kit (Atmospherics)

Material, fire and recycling

Heat exchange (factor × surface): radiation 0.52, convection 0.52, sun 0.52

Raw values from the game code (5)

Field names as in the game code, untranslated. Useful for mods and exact limits.

DeviceAtmospherics.outputSetting50
DeviceAtmospherics.pressurePerTick750
DeviceAtmospherics.MinSetting3.15
DeviceAtmospherics.MaxSetting1,272.2
DeviceAtmospherics.ConnectionTypeFlatExhaustive

See also

  • Heating and cooling: wall heater, wall cooler, air conditioner, radiatorsWhich device moves heat where, how much energy a room needs, what each planet demands and a thermostat program with heater and cooler.
  • Venus: heat and acidVenus in detail: 239 kPa outside pressure, 464 °C day and night, almost a third hydrochloric acid in the air, no ice – but the strongest sun in the game. With worked examples for walls and air.
  • Vulcan: lava and methane airVulcan in detail: methane, pollutant, CO₂ and hydrogen without oxygen, 127 °C at night and over 1,100 °C at noon, lava, ash and solar storms, rich ores on the surface.
Esc
↑ ↓ selectEnter open/ opens search anywhere