PrefabStructureLargeExtendableRadiator Hash-566775170in the hash lookup
General paintable Game 0.2.6428.27798

Overview

Large Extendable Radiator (StructureLargeExtendableRadiator) in Stationeers: device, hash -566775170, 10 W. With build steps, 43 IC10 logic values and…

The large extendable radiator takes up 3 × 11 × 3 spots on the small grid, about 1.5 × 5.4 × 1.5 m. Unlike the medium radiators it hangs on a liquid loop – input and output are liquid pipes. It also has a data port; it needs no power. With radiation 73.6 and convection 0.74 it is a device for vacuum and for large amounts of heat.

What the logic values do according to the game code:

  • Open: it only exchanges heat when extended. Retracted, radiation, convection and solar heating are zero. In return, retracting protects it from storms: it only takes weather damage while extended.
  • Horizontal: turns the panel about the vertical axis, 0 to 360 degrees. By hand you do it with the wrench, 10 degrees per click, holding the key for small increments 1 degree. This model has no tilt (Vertical).

The sun works against you. The game checks how directly the sun falls on either side of the panel and how much of it is blocked – at five measuring points, 20 % each. The more sun, the more it heats the panel. As long as the surroundings are colder than the contents, radiation also drops: in shade the full 73.6 count, in full sun only about 46. So for cooling, turn it edge-on to the sun or put it in the shade. When you look at it, it shows its solar heating value in percent and its condition.

Readable are Temperature, Pressure, the fractions inside (200 litres) plus EnergyRadiated and EnergyConvected. At 72 J per mole and kelvin a litre of water stores about 4,000 J per kelvin – that is why it runs on liquid.

It is built in three steps:

  1. place the Kit (Large Extendable Radiator),
  2. attach two steel sheets with the welding torch,
  3. insert five stellite glass sheets – this stage is removed with the crowbar.

How liquid loops are planned is covered in Heat exchangers and heat transport: pipe to pipe, gas to liquid.

IC10 and logic

43 logic values, 43 readable and 4 writable.

  • Open RW 2
  • Pressure R 5
  • Temperature R 6
  • Lock RW 10
  • Setting RW 12
  • RatioOxygen R 14
  • RatioCarbonDioxide R 15
  • RatioNitrogen R 16
  • RatioPollutant R 17
  • RatioMethane R 18
  • RatioWater R 19
  • Horizontal RW 20
  • Maximum R 23
  • Ratio R 24
  • TotalMoles R 66
  • RatioNitrousOxide R 83
  • PrefabHash R 84
  • Combustion R 98
  • RatioLiquidNitrogen R 177
  • RatioLiquidOxygen R 183
  • RatioLiquidMethane R 188
  • RatioSteam R 193
  • RatioLiquidCarbonDioxide R 199
  • RatioLiquidPollutant R 204
  • RatioLiquidNitrousOxide R 209
  • ReferenceId R 217
  • RatioHydrogen R 252
  • RatioLiquidHydrogen R 253
  • RatioPollutedWater R 254
  • NameHash R 268
  • RatioHydrazine R 283
  • RatioLiquidHydrazine R 284
  • RatioLiquidAlcohol R 285
  • RatioHelium R 286
  • RatioLiquidSodiumChloride R 287
  • RatioSilanol R 288
  • RatioLiquidSilanol R 289
  • RatioHydrochloricAcid R 290
  • RatioLiquidHydrochloricAcid R 291
  • RatioOzone R 292
  • RatioLiquidOzone R 293
  • EnergyConvected R 354
  • EnergyRadiated R 355

Example: address by name

Reads Temperature, shows the value on the IC housing and writes Setting. Name the device with the labeller first; devices with the same name are addressed together.

# Large Extendable Radiator address by name
define DEVICE -566775170  # StructureLargeExtendableRadiator
define NAME HASH("Large Extendable Radiator")  # name in game (labeller)
define TARGET 50  # Setting target value (Setting)
alias value r0

start:
yield
lbn value DEVICE NAME Temperature 0  # 0 = average of all with this name
bnan value start  # no device with this name
s db Setting value  # show on the housing
sbn DEVICE NAME Setting TARGET  # set value
j start

Connections

2Liquid3Liquid1
Schematic: inputs left, outputs right, waste on top, power and data at the bottom. Position and spacing do not match the model.
  1. 1Data
  2. 2Liquid pipe · input
  3. 3Liquid pipe · output

Building and deconstruction

Grid: small grid (0.5 m) · mounting: free in the grid

  1. 1
  2. 2

    Build stage 2

    Take back with Angle Grinder

  3. 3

    Build stage 3

    Take back with Crowbar

Built with: Kit (Large Extendable Radiator)

Material, fire and recycling

Heat exchange (factor × surface): radiation 73.56, convection 0.736, sun 0

Raw values from the game code (7)

Field names as in the game code, untranslated. Useful for mods and exact limits.

LargeExtendableRadiator._solarRadiationRetardationDenominator4
Radiator.volume200
DeviceAtmospherics.outputSetting50
DeviceAtmospherics.pressurePerTick101.3
DeviceAtmospherics.MinSetting0
DeviceAtmospherics.MaxSetting100
DeviceAtmospherics.ConnectionTypeExhaustive