Overview
Combustion Centrifuge (StructureCombustionCentrifuge) in Stationeers: device, hash 1238905683, 50 W. With build steps, 113 IC10 logic values and connection…
The combustion centrifuge separates mixtures like the normal Centrifuge, but is driven by gas. Its connections and logic values show this: it has a gas input and a gas output, readable Combustion, Rpm and Stress, writable Throttle and CombustionLimiter. On top come pressure, temperature and gas ratios for the interior, the input and the output.
One slot takes a programmable chip. That lets the control run inside the device, without its own IC housing. A chip could, for example, adjust Throttle based on Rpm and Stress. The game data does not state which values are safe – watch Stress when you open the throttle.
Connections: import and export slot, chute input and output, data, power, gas input and output. The base draw is only 50 W, half that of the normal centrifuge.
The kit Kit (Combustion Centrifuge) needs a tier 2 autolathe: steel 20, invar 10, constantan 5. It is built in three stages: kit, two steel sheets with the welding torch, one cable coil. More about separating in Recycling and centrifuge: getting material back.
IC10 and logic
113 logic values, 112 readable and 6 writable.
-
PowerR 1 -
OpenRW 2 -
ErrorR 4 -
PressureR 5 -
TemperatureR 6 -
LockRW 10 -
ReagentsR 13 -
RatioOxygenR 14 -
RatioCarbonDioxideR 15 -
RatioNitrogenR 16 -
RatioPollutantR 17 -
RatioMethaneR 18 -
RatioWaterR 19 -
OnRW 28 -
RequiredPowerR 33 -
ClearMemoryW 62 -
ExportCountR 63 -
ImportCountR 64 -
TotalMolesR 66 -
RatioNitrousOxideR 83 -
PrefabHashR 84 -
CombustionR 98 -
PressureInputR 106 -
TemperatureInputR 107 -
RatioOxygenInputR 108 -
RatioCarbonDioxideInputR 109 -
RatioNitrogenInputR 110 -
RatioPollutantInputR 111 -
RatioMethaneInputR 112 -
RatioWaterInputR 113 -
RatioNitrousOxideInputR 114 -
TotalMolesInputR 115 -
PressureOutputR 126 -
TemperatureOutputR 127 -
RatioOxygenOutputR 128 -
RatioCarbonDioxideOutputR 129 -
RatioNitrogenOutputR 130 -
RatioPollutantOutputR 131 -
RatioMethaneOutputR 132 -
RatioWaterOutputR 133 -
RatioNitrousOxideOutputR 134 -
TotalMolesOutputR 135 -
CombustionInputR 146 -
CombustionOutputR 148 -
CombustionLimiterRW 153 -
ThrottleRW 154 -
RpmR 155 -
StressR 156 -
RatioLiquidNitrogenR 177 -
RatioLiquidNitrogenInputR 178 -
RatioLiquidNitrogenOutputR 180 -
RatioLiquidOxygenR 183 -
RatioLiquidOxygenInputR 184 -
RatioLiquidOxygenOutputR 186 -
RatioLiquidMethaneR 188 -
RatioLiquidMethaneInputR 189 -
RatioLiquidMethaneOutputR 191 -
RatioSteamR 193 -
RatioSteamInputR 194 -
RatioSteamOutputR 196 -
RatioLiquidCarbonDioxideR 199 -
RatioLiquidCarbonDioxideInputR 200 -
RatioLiquidCarbonDioxideOutputR 202 -
RatioLiquidPollutantR 204 -
RatioLiquidPollutantInputR 205 -
RatioLiquidPollutantOutputR 207 -
RatioLiquidNitrousOxideR 209 -
RatioLiquidNitrousOxideInputR 210 -
RatioLiquidNitrousOxideOutputR 212 -
ReferenceIdR 217 -
RatioHydrogenR 252 -
RatioLiquidHydrogenR 253 -
RatioPollutedWaterR 254 -
NameHashR 268 -
RatioHydrazineR 283 -
RatioLiquidHydrazineR 284 -
RatioLiquidAlcoholR 285 -
RatioHeliumR 286 -
RatioLiquidSodiumChlorideR 287 -
RatioSilanolR 288 -
RatioLiquidSilanolR 289 -
RatioHydrochloricAcidR 290 -
RatioLiquidHydrochloricAcidR 291 -
RatioOzoneR 292 -
RatioLiquidOzoneR 293 -
RatioHydrogenInputR 294 -
RatioHydrogenOutputR 296 -
RatioLiquidHydrogenInputR 298 -
RatioLiquidHydrogenOutputR 300 -
RatioPollutedWaterInputR 302 -
RatioPollutedWaterOutputR 304 -
RatioHydrazineInputR 306 -
RatioHydrazineOutputR 308 -
RatioLiquidHydrazineInputR 310 -
RatioLiquidHydrazineOutputR 312 -
RatioLiquidAlcoholInputR 314 -
RatioLiquidAlcoholOutputR 316 -
RatioHeliumInputR 318 -
RatioHeliumOutputR 320 -
RatioLiquidSodiumChlorideInputR 322 -
RatioLiquidSodiumChlorideOutputR 324 -
RatioSilanolInputR 326 -
RatioSilanolOutputR 328 -
RatioLiquidSilanolInputR 330 -
RatioLiquidSilanolOutputR 332 -
RatioHydrochloricAcidInputR 334 -
RatioHydrochloricAcidOutputR 336 -
RatioLiquidHydrochloricAcidInputR 338 -
RatioLiquidHydrochloricAcidOutputR 340 -
RatioOzoneInputR 342 -
RatioOzoneOutputR 344 -
RatioLiquidOzoneInputR 346 -
RatioLiquidOzoneOutputR 348
Values per slot (slot logic)
| Slot value | readable in slot | writable in slot | Number |
|---|---|---|---|
Occupied | 0, 1, 2 | – | 1 |
OccupantHash | 0, 1, 2 | – | 2 |
Quantity | 0, 1, 2 | – | 3 |
Damage | 0, 1, 2 | – | 4 |
Class | 0, 1, 2 | – | 12 |
MaxQuantity | 0, 1, 2 | – | 15 |
PrefabHash | 0, 1, 2 | – | 17 |
SortingClass | 0, 1, 2 | – | 24 |
ReferenceId | 0, 1, 2 | – | 26 |
FreeSlots | 0, 1, 2 | – | 31 |
TotalSlots | 0, 1, 2 | – | 32 |
Example: address by name
Reads Temperature, shows the value on the IC housing and writes On. Name the device with the labeller first; devices with the same name are addressed together.
# Combustion Centrifuge address by name
define DEVICE 1238905683 # StructureCombustionCentrifuge
define NAME HASH("Combustion Centrifuge") # name in game (labeller)
define TARGET 1 # On 1 = on
alias value r0
start:
yield
lbn value DEVICE NAME Temperature 0 # 0 = average of all with this name
bnan value start # no device with this name
s db Setting value # show on the housing
sbn DEVICE NAME On TARGET # set value
j startAcademy: devices by name Academy: batch modes IC10 academy IC10 editor
Connections
- 1Chute · input
- 2Chute · output
- 3Data
- 4Power
- 5Gas pipe · input
- 6Gas pipe · output
Slots and modes
| # | Slot | Takes |
|---|---|---|
| 0 | Import | None |
| 1 | Export | None |
| 2 | Programmable Chip | ProgrammableChip |
Building and deconstruction
Grid: small grid (0.5 m) · mounting: free in the grid
- 1
- 2
- 3
Total material
Deconstruction returns
Built with: Kit (Combustion Centrifuge)
Material, fire and recycling
Heat exchange (factor × surface): radiation 0, convection 0, sun 0
Raw values from the game code (7)
Field names as in the game code, untranslated. Useful for mods and exact limits.
DeviceInputOutputImportExport.ExportConnectionId | 1 |
DeviceInputOutputImport.ImportConnectionId | 0 |
DeviceAtmospherics.outputSetting | 50 |
DeviceAtmospherics.pressurePerTick | 10 |
DeviceAtmospherics.MinSetting | 0 |
DeviceAtmospherics.MaxSetting | 100 |
DeviceAtmospherics.ConnectionType | FlatExhaustive |
See also
- Recycling and centrifuge: getting material backWhat the recycler returns from old parts, how the centrifuge separates mixtures back into pure ores, what the combustion centrifuge does differently and what a recycling line looks like.