Day 223 of 365 · Pro · Month 8: Production

Project: production line

A production line with a status display: check material, start only in the “ready” state, show progress, detect a jam and a missing lathe.

Project 40 min Week 32

What you learn today

  • Check materials, fabricate, report
  • Detect jams
  • Status display

This week showed you the parts: rmap and lr for missing material, fabricators via logic, centrifuge and jam, ice crusher, start lock. Now you build a small production line that explains itself.

The plant

DevicePrefabName
autolatheStructureAutolathe“Drehbank”
buttonStructureLogicButton“Start”
two LED displaysStructureConsoleLED5“Status”, “Fortschritt”

The lathe makes iron frames. One piece needs 4 iron.

One status instead of many lights

StatusMeaningColour
0readygreen
1fabricatingblue
2material missingyellow
3jam at the outputred
4lathe unreachablered

The chip checks from unimportant to important, every hit overwrites the previous one. Fabricating beats material shortage: a running job already has its material. A jam beats both, and the missing lathe beats everything.

Starting only in status 0

bnez status start

If the status is not “ready”, the chip jumps back before it even reads the button. That way nobody starts a job without material or into a jam.

Milestones

  1. Check material: below 4 units status 2, otherwise 0
  2. Fabricate: start by button, status 1 during the job
  3. Progress in percent
  4. Jam after 20 ticks of occupied output: status 3, red
  5. Lathe missing: status 4, red
Tip

The colour depends only on the status. First yellow or green with select colour status … – every status other than 0 starts as yellow –, then blue for 1 and red from 3. Three lines, no jump.

Project task

Task

Build the production line following the tables. The lathe makes iron frames (ItemIronFrames). defines and reading are there, recipe choice, status, colours, progress and the start are missing.

Milestones

  1. Milestone 1: check material
  2. Milestone 2: fabricate by button
  3. Milestone 3: progress
  4. Milestone 4: detect a jam
  5. Milestone 5: lathe missing

Hints

Hint 1

Status: move status READY, then shortage, working, jam, missing – each with select status … status.

Hint 2

Jam counter as with the centrifuge: add, then mul with “slot 1 occupied”.

Hint 3

Start: bnez status start, check the button with sgtz, then Activate 1.

Quiz

2 questions. You pass from 60 % – the server does the grading.